Slump test and compaction factor test
WebbThe concrete slump test and compaction factor test are used to determine the consistency of fresh concrete before it sets. This paper has focused on testing the 54 mixes having Webb18 sep. 2024 · 2.Compaction factor test. 3.Crushing strength test. Slump Test: This test is conducted to determine the work ability of concrete. It needs a slump cone for test . Slump cone is a vessel in the shape of a frustum of a cone with diameter at bottom 200 mm and 50 mm at top and 300 mm high.
Slump test and compaction factor test
Did you know?
WebbDiscussion and Conclusion. Compaction factor normally falls between the range of 0.8 – 0.92. This test gives more accurate results than slump test while dealing with relatively dryer concrete mixes. Compaction factor test gives more precise and sensitive results. Compaction factor of 0.75 to 0.80 are used for concreting of shallow sections ... WebbSlump Test 2. Compaction Factor Test 3. Vee-bee Consistometer Test. In this study, the slump-cone test and compaction factor tests were carried out to determine the workability of concrete. The test procedures are given below: DETERMINATION OF WORKABILITY BY SLUMP-CONE TEST:
WebbCompaction Factor Test: Theory: The compaction factor test is carried out to measure the degree of workability of fresh concrete with regard to the internal energy required for compacting the concrete thoroughly. Apparatus: 1. Compaction Factor Machine, 2. Weighing Machine, 3. Steel Trowel Or Mechanical Vibrator. WebbCompaction factor= (W1-W)/ (W2-W) where W is the weight of empty cylinder. The bulky apparatus and the need for balance limit the using of the test at construction fields. the using of hand compacting may not reflect the field condition and produce less effective results. However, the test is more precise compared to slump test and it is a ...
WebbAnswer (1 of 2): If you are talking about the accuracy of the results then u can go with compaction factor test.if you are talking about the simple way u can go with slump cone test.slumpcone test is very simple and gives nearly accurate values if done perfectly. Compaction factor test is very s... Webb14 maj 2024 · Compaction factor test is developed by road research laboratory UK and is precise and accurate than slump test. The test is done when the concrete is to be compacted by vibration and continually fail to slump. Also read : Bitumen – 9 lab tests on bitumen for flexible pavements. Also read : Timber – Five important quality tests
Webb28 okt. 2014 · Generally we specify workability of concrete in terms of its slump test value. But sometimes it is also specified by another test called compaction factor. The relation between slump and compaction factor is roughly as follows. Relation Between Slump & Compaction factor Share this: Email Print More
Webbtest on fresh concrete 1. slump cone test 2. flow table 3. compaction factor 4. vee bee test test on hardened concrete 1. compressive strength – cube & cylinder 2. flexture test 3. modulus of elastics test on bitumen 1. penetration 2. softening point 3. ductility 4. viscosity 5. elastic recovery 6. storage stability test on aggregates 1 ... how to set up a fishing rod for lake troutWebb23 apr. 2024 · Slump test is a laboratory or at site test used to measure the consistency of concrete. ... Compaction factor 0.75 – 0.8: Low: Mass concrete, lightly reinforced slab, … how to set up a fishing rod with floatWebb25 maj 2013 · 1.What are the main differences between Slump Test and Compacting Factor Test. Ans:-The main difference between both is that compaction factor test is … notes on qbasicWebbYash Scientific Multi Products, New Delhi, Delhi - Established in 2024, we are Manufacturer of 2000 KN Compressor Testing Machines, ... Slump Test Apparatus, Compaction Factor Apparatus and Testing & Measuring Equipments. X. Yash Scientific Multi Products. New Delhi, Delhi GST 07DOHPD3238B1ZF. is a member of IndiaMART Verified Supplier ... how to set up a fitbit account for a childWebb2) Compacting factor test: It is more accurate than a slump test. It is suitable for concrete mixes of medium and low workability. It is suitable for determining workability in the laboratory. 3) Vee-bee consistometer: The time required for complete remoulding of concrete in seconds after placed in the mould with a slump how to set up a fishing rod and reelWebbOn 18 August 2016, I and my group, F2, had carried out building workshop practical 1, which is the slump test and compaction factor test. Based on my notes, I learnt that slump test is carry out to determine the effect of slump on different water/cement ratio and concrete mix while the compacting factor test is carried out to determine the workability … how to set up a fitbit charge 4 instructionsWebbThe property of concrete which determines the amount of useful internal work, necessary to produce full compaction i.e workability is the amount of energy to... how to set up a fitbit